Model
|
Configuration
|
ESS1204
8E500P4
|
MPPT-SCM 48240R
|
INVERTER-HP
12048DR
|
BATTERY-LFP
48100R*5
|
Total energy
|
240A(60A*4)
|
12KW
|
500AH(100AH*5)
|
25.6kwh
|
Battery
|
Description
|
Normal
specification
|
1
|
Rated Voltage
|
51.2V
|
2
|
Rated Capacity
|
500Ah
|
3
|
Rated Energy
|
25.6KWH
|
4
|
Battery Configuration
|
5.12KWH(16S1P) *5PCS
|
5
|
Battery Cell
|
3.2V100AH 80PCS
|
Standard Charge
|
1
|
Operation temperature range @charging
|
0~45℃
|
2
|
Rated charge voltage
|
55.2±0.4V
|
3
|
Max charge
voltage
|
56.8±0.4V
|
4
|
Overcharge protection
|
58.4±0.4V
|
5
|
Allowed MAX charge
current(Total)
|
275A withstand 30s
(every pack 55A)
|
6
|
Peak charge current(Total)
|
300A withstand 5s
(every pack 60A)
|
7
|
Rated charge
current(Total)
|
250A (every pack 50A)
|
8
|
Recommend
charge current(Total)
|
<250A
|
Standard discharge
|
1
|
Operation temperature range @discharging
|
-20~60℃
|
2
|
Output Voltage Range
|
40~56Vdc
|
3
|
Recommend Working
Range
|
46~54Vdc
|
4
|
Discharge
Cut-off voltage
|
40V
|
5
|
Allowed MAX discharge current(Total)
|
550A withstand 30s
(every pack 110A)
|
6
|
Peak discharge current(Total)
|
600A withstand 5s
(every pack 120A)
|
7
|
Rated discharge
current(Total)
|
500A (every pack 200A)
|
8
|
Recommend
discharge current(Total)
|
<400A
|
Communication
|
1
|
RS485
|
For LCD remote
|
2
|
CAN
|
PC control and monitor
|
Inverter
(built-in)
|
Description
|
Normal
specification
|
1
|
Rated Power
|
12KW
|
2
|
Output Waveform
|
Pure Sine Wave/Same as
input (Bypass Mode)
|
3
|
Output Voltage
|
240Vac(H-H)/120Vac(H-N)
±10% RMS
|
4
|
Output Frequency
|
50 or 60± 0.3Hz
(Inverter mode by sw4 setting)
|
5
|
Typical Transfer Time
|
4-6ms
typical,10ms(Max)
|
6
|
THD
|
< 3%(Rated voltage
full R load)
|
7
|
AC Input Range
|
184-253Vac (UPS mode)
or 140-270Vac (GEN mode)
|
8
|
Customized AC Charger
|
Battery type selector
position 9, special design for LFP, make the battery cycle life Maximization
|
9
|
MAX AC Charge Current
|
90A
|
10
|
Battery priority
Function
|
Setting by SW5 on
position 1 (inverter mode valid), AC automatic come in when battery voltage
low alarm at 48Vdc or 50Vdc
|
11
|
AC Bypass without
charging
|
Battery type selector
position 0
|
MPPT
(built-in)
|
Description
|
Normal
specification
|
1
|
PV POWER
|
3.0KW*4
|
2
|
PV Input Voltage
|
60-145Vdc
|
3
|
MPPT Charging Voltage
|
56.0Vdc (Fast
charging)/54Vdc (Float charging)
|
4
|
MPPT Output Current
|
60A*4
|
Mechanical
Characteristics
|
ESS1204
8E500P4
|
Dimension H*W*D
|
Shipping H*W*D
|
Weight(N.W.)
|
Weight(G.W.)
|
1810*560*785mm
|
1960*700*870mm
|
450KG
|
500KG
|