Battery Description
Normal specification
1 Rated Voltage 51.2V
2 Rated Capacity 800Ah
3 Rated Energy 40.96KWH
4 Battery Configuration 10.24KWH(16S2P) *4PCS
5 Battery Cell 3.2V100AH 128PCS
Standard Charge
1 Operation temperature range @charging 0~45℃
2 Rated charge voltage 55.2±0.4V
3 Max charge voltage 56.8±0.4V
4 Overcharge protection 58.4±0.4V
5 Allowed MAX charge current(Total) 440A withstand 30s (every pack 55A)
6 Peak charge current(Total) 480A withstand 5s (every pack 60A)
7 Rated charge current(Total) 400A (every pack 100A)
8 Recommend charge current(Total) <300A
Standard discharge
1 Operation temperature range @discharging -20~60℃
2 Output Voltage Range 40~56Vdc
3 Recommend Working Range 46~54Vdc
4 Discharge Cut-off voltage 40V
5 Allowed MAX discharge current(Total) 880A withstand 30s (every pack 110A)
6 Peak discharge current(Total) 960A withstand 5s (every pack 120A)
7 Rated discharge current(Total) 800A (every pack 200A)
8 Recommend discharge current(Total) <600A
Communication
1 RS485 For LCD remote
2 CAN PC control and monitor
Inverter (built-in) Description
Normal specification
1 Rated Power 15KW
2 Output Waveform Pure Sine Wave/Same as input (Bypass Mode)
3 Output Voltage 240Vac(H-H)/120Vac(H-N) ±10% RMS
4 Output Frequency 50 or 60± 0.3Hz (Inverter mode by sw4 setting)
5 Typical Transfer Time 4-6ms typical,10ms(Max)
6 THD < 3%(Rated voltage full R load)
7 AC Input Range 184-253Vac (UPS mode) or 140-270Vac (GEN mode)
8 Customized AC Charger Battery type selector position 9, special design for LFP, make the battery cycle life Maximization
9 MAX AC Charge Current 100A
10 Battery priority Function Setting by SW5 on position 1 (inverter mode valid), AC automatic come in when battery voltage low alarm at 48Vdc or 50Vdc
11 AC Bypass without charging Battery type selector position 0
MPPT (built-in) Description
Normal specification
1 PV POWER 3.5KW*4
2 PV Input Voltage 60-145Vdc
3 MPPT Charging Voltage 56.0Vdc (Fast charging)/54Vdc (Float charging)
4 MPPT Output Current 60A*4
Model Configuration
ESS15048E800P4 MPPT INVERTER BATTERY Energy
240A(50A*4) 15KW 800AH(200AH*4) 40.96kwh
Mechanical Characteristics
ESS15048E800P4 Dimension H*W*D Shipping H*W*D Weight(N.W.) Weight(G.W.)
1610*560*960mm 1790*700*1050mm 560KG 610KG
BMS
The batteries are supplied with a LiFePO4 Battery Management System (BMS)that can monitor and optimized each single prismatic cell during charge & discharge, to protect the battery pack overcharge, over discharge, short circuit. Overall, the BMS helps to ensure safe and accurate running.

Items

Content (for each cell)

Criterion

Alarm LED(red)

Over

charge

Over-chargewarning

3700mv

once/3s flash, keep output

Over-charge protection

3750mv

once/1s flash, relay cut off

Over-chargewarningrelease

3400mv


Over-charge protectionrelease

3350mv


Over-chargerelease method

Discharging(Automatic)


Over discharge

Over-dischargewarning

2700mv

once/3s flash, keep output

Over-discharge protection

2500mv

once/1s flash, relay cut off

Over-dischargewarningrelease

2900mv


Over-discharge protectionrelease

2800mv


Over-dischargerelease method

Charging


Over current

(CHG&DISCHG)

Overcurrent warning

110% rated

once/1s flash, 30s off

Overcurrent protection(PEAK)

120% rated

Lightning, delay 10s off

relay cut off

Overcurrentrelease method(CHG)

Restart


Overcurrentrelease method(DISCHG)

Cut off loads and Restart


Over & Lower Temp

(Discharging)

Overtemperature

Warning@55℃

once/3s flash, keep output

Protection@60℃

once/1s flash, relay cut off

WarningRelease@40℃


ProtectionRelease@55℃


Lower temperature

Warning@-20℃

once/3s flash, keep output

Protection@-25℃

once/1s flash, relay cut off

WarningRelease@-15℃


ProtectionRelease@-20℃


Over & Lower Temp(Charging)

Overtemperature

Warning@45℃

once/3s flash, keep output

Protection@50℃

once/1s flash, relay cut off

WarningRelease@40℃


ProtectionRelease@45℃


Lower temperature

Warning@0℃

once/3s flash, keep output

Protection@-5℃

once/1s flash, relay cut off

WarningRelease@5℃


ProtectionRelease@0℃



LCD Module Introduction
The LCD display battery and inverter working information in the cabinet





ESS15048E800P4-40.96KWH Single-phase off-grid energy storage system
DOWNLOAD PDF

Function description


Item

Name

Description

1

INV power switch

Power saver auto: inverter work in saver mode

Inverter OFF: inverter power off

Inverter ON: inverter work in normal mode

2

Inverter indicator LED

CHG: inverter working in battery charge mode

INV: inverter working in battery discharge mode

Alarm: inverter warning or fault

3

LCD Screen

Show the system working information

4

Battery indicator LED

RUN: battery working normal

Alarm: battery warning or fault

Display ON/OFF

5

Button SYS

Press button, LCD will show ESS info directly

Button BATT

Press button, LCD will show BATT info directly

Button INV

Press button, LCD will show INV info directly

Button MPPT

Press button, LCD will show MPPT info directly



Note:
1. The connector of Inverter port is RJ45 type, connector of Battery is RJ11 type, never insert the wrong position or damage will happen and invalid warranty.
2. DISPLAY ON/OFF: touch any button will lighting the LCD, keep press the button, the current screen will hold for checking current module information.
Display introduction
ESS INFO display



Charging-Power

 MPPT charging power total

Energy-hour

 Solar generator energy in current hour

Energy-Day

Solar generator energy today

Energy-Total

Solar generator energy total

AC Load

Current AC loads power inverter take

BAT-Voltage

System battery voltage

Total Bat capacity

System rated battery capacity in total

Remain Bat capacity

System remain battery capacity in total

Discharge-Time

System estimated time to discharge battery empty in current condition

Charge- Time

System estimated time to charging battery full in current condition

MPPT-Status

All MPPT working status in system

00: normal  01: warning occur  02: fault occur

Inverter-Status

Inverter working status in system

00: normal  01: warning occur  02: fault occur

Battery-Status

All Battery working status in system

00: normal  01: warning occur  02: fault occur


BATTERY PACK display


first battery info window

Total-battery pack

Total battery packs in system

Battery V:

Current ID battery voltage

Rated Cap:

Battery rated capacity of current ID

Current I:

Positive means charge, Negative means discharge

Current Cap:

Remain capacity of current ID battery

CHG time:

Estimated time to charging battery full

Current SOC:

Remain SOC of current ID battery

DIS time:

Estimated time to discharge battery empty

Cycle times:

Battery cycle times of current ID

ID:

Current battery identity number

Alarm status:

Ref the battery pack alarm code table

OVP times

Number of battery voltage alarm times

OCP times

Number of battery current alarm times

OTP times

Number of battery temperature alarm times


Battery pack alarm code table

0000

normal

0100

Cell Over-voltage Warning

0200

Cell Over-voltage Protection

0400

Cell Low-voltage Warning

0800

Cell Low-voltage Protection

0010

Cell Over-temp Warning

0020

Cell Over-temp Protection

0040

Cell Low-temp Warning

0080

Cell Low-temp Protection

0001

Discharge Over-current Warning

0002

Discharge Over-current Protection

0004

Charge Over-current Warning

0008

Charge Over-current Protection




second battery info window

ID

Current battery identity number

C1——C16

Internal cells voltage

T1——T4

Internal temperature detecting value

Max V

Maximum cell voltage

Min V

Minimum cell voltage

Max T

Maximum internal temperature detecting value

Min T

Minimum internal temperature detecting value


INVERTER INFO display


Rated-Power

Inverter rated power

Input AC

Current utility or generator AC voltage

Output AC

Inverter output AC voltage

Batt DC

Current battery voltage

Output Freq

Inverter output AC frequency

Output Load

Current AC loads percentage inverter take

Work mode

Charging or Inverter

Mode Transfer times

Inverter working mode transfer times

Alarm

Ref inverter 3.3.9

Fault

Ref inverter 3.3.9




MPPT INFO display


ID

Current MPPT identity number

PV Input Voltage

Current MPPT PV input voltage

Charging Current

Current MPPT charging current

Charging Power

Current MPPT charging power

Charge Voltage

Current MPPT charging voltage

Unit HS Temperature

Current MPPT internal temperature

Warning code

Ref MPPT 3.1.3

Fault code

Ref MPPT 3.1.3

Fault times

Current MPPT occurs fault times


Storage & Transportation
* Based on the character of cell, proper environment for transportation of LiFePO4 battery pack need to be created to protect the battery.
* Battery should be stayed in the ware house -20℃~35℃ where it’s dry, clean, shade, and well-ventilated.
* The battery should be stored in 50% SOC during transportation.
* The battery need to be charged every 6 months if out of use.
* Keep the battery against dropping, turning over and serious stacking during loading.

Warning & Tips
Please read and follow the specification and caution remarks on battery surface before use the battery. Improper use may cause heat, fire, rupture, damage or capacity deterioration of the battery. Describes is not responsible for any accidents caused by the usage without following our specification.
Warning!
* The battery must be far away from heat source, high voltage, and avoid to be exposed in sunshine for long time.
* Never throw the battery into water.
* Never connect the positive and negative of battery with metal.
* Never sheep or store battery together with metal.
* Never reverse two electrodes when use the battery.
* Never disassemble the battery without manufacturer's permission and guidance.
* Never knock, throw or trample the battery.
Tips!
* Keep the battery against high temperature. Otherwise it will cause battery heat, get into fire or lose some function and reduce the life.
* When battery run out of power, please charge your battery timely (≤15day).
* Please use the matched or suggested charger for this battery.
* If battery emit peculiar smell, heating, distortion or appear any abnormity during working or storage, please stop using and take it out from device.
* If the battery leaks and get into the eyes or skin, do not wipe, instead, rinse it with clean water and see doctor immediately.
* Please far away from children or pets.
* Do not put disuse battery into a fire or water.
* It is strictly prohibited any series between the battery packs.

ESS15048E800P4-40.96KWH Single-phase off-grid energy storage system





ESS15048E800P4-40.96KWH Single-phase off-grid energy storage system
DOWNLOAD PDF


Battery Description
Normal specification
1 Rated Voltage 51.2V
2 Rated Capacity 800Ah
3 Rated Energy 40.96KWH
4 Battery Configuration 10.24KWH(16S2P) *4PCS
5 Battery Cell 3.2V100AH 128PCS
Standard Charge
1 Operation temperature range @charging 0~45℃
2 Rated charge voltage 55.2±0.4V
3 Max charge voltage 56.8±0.4V
4 Overcharge protection 58.4±0.4V
5 Allowed MAX charge current(Total) 440A withstand 30s (every pack 55A)
6 Peak charge current(Total) 480A withstand 5s (every pack 60A)
7 Rated charge current(Total) 400A (every pack 100A)
8 Recommend charge current(Total) <300A
Standard discharge
1 Operation temperature range @discharging -20~60℃
2 Output Voltage Range 40~56Vdc
3 Recommend Working Range 46~54Vdc
4 Discharge Cut-off voltage 40V
5 Allowed MAX discharge current(Total) 880A withstand 30s (every pack 110A)
6 Peak discharge current(Total) 960A withstand 5s (every pack 120A)
7 Rated discharge current(Total) 800A (every pack 200A)
8 Recommend discharge current(Total) <600A
Communication
1 RS485 For LCD remote
2 CAN PC control and monitor
Inverter (built-in) Description
Normal specification
1 Rated Power 15KW
2 Output Waveform Pure Sine Wave/Same as input (Bypass Mode)
3 Output Voltage 240Vac(H-H)/120Vac(H-N) ±10% RMS
4 Output Frequency 50 or 60± 0.3Hz (Inverter mode by sw4 setting)
5 Typical Transfer Time 4-6ms typical,10ms(Max)
6 THD < 3%(Rated voltage full R load)
7 AC Input Range 184-253Vac (UPS mode) or 140-270Vac (GEN mode)
8 Customized AC Charger Battery type selector position 9, special design for LFP, make the battery cycle life Maximization
9 MAX AC Charge Current 100A
10 Battery priority Function Setting by SW5 on position 1 (inverter mode valid), AC automatic come in when battery voltage low alarm at 48Vdc or 50Vdc
11 AC Bypass without charging Battery type selector position 0
MPPT (built-in) Description
Normal specification
1 PV POWER 3.5KW*4
2 PV Input Voltage 60-145Vdc
3 MPPT Charging Voltage 56.0Vdc (Fast charging)/54Vdc (Float charging)
4 MPPT Output Current 60A*4
Model Configuration
ESS15048E800P4 MPPT INVERTER BATTERY Energy
240A(50A*4) 15KW 800AH(200AH*4) 40.96kwh
Mechanical Characteristics
ESS15048E800P4 Dimension H*W*D Shipping H*W*D Weight(N.W.) Weight(G.W.)
1610*560*960mm 1790*700*1050mm 560KG 610KG
BMS
The batteries are supplied with a LiFePO4 Battery Management System (BMS)that can monitor and optimized each single prismatic cell during charge & discharge, to protect the battery pack overcharge, over discharge, short circuit. Overall, the BMS helps to ensure safe and accurate running.

Items

Content (for each cell)

Criterion

Alarm LED(red)

Over

charge

Over-chargewarning

3700mv

once/3s flash, keep output

Over-charge protection

3750mv

once/1s flash, relay cut off

Over-chargewarningrelease

3400mv


Over-charge protectionrelease

3350mv


Over-chargerelease method

Discharging(Automatic)


Over discharge

Over-dischargewarning

2700mv

once/3s flash, keep output

Over-discharge protection

2500mv

once/1s flash, relay cut off

Over-dischargewarningrelease

2900mv


Over-discharge protectionrelease

2800mv


Over-dischargerelease method

Charging


Over current

(CHG&DISCHG)

Overcurrent warning

110% rated

once/1s flash, 30s off

Overcurrent protection(PEAK)

120% rated

Lightning, delay 10s off

relay cut off

Overcurrentrelease method(CHG)

Restart


Overcurrentrelease method(DISCHG)

Cut off loads and Restart


Over & Lower Temp

(Discharging)

Overtemperature

Warning@55℃

once/3s flash, keep output

Protection@60℃

once/1s flash, relay cut off

WarningRelease@40℃


ProtectionRelease@55℃


Lower temperature

Warning@-20℃

once/3s flash, keep output

Protection@-25℃

once/1s flash, relay cut off

WarningRelease@-15℃


ProtectionRelease@-20℃


Over & Lower Temp(Charging)

Overtemperature

Warning@45℃

once/3s flash, keep output

Protection@50℃

once/1s flash, relay cut off

WarningRelease@40℃


ProtectionRelease@45℃


Lower temperature

Warning@0℃

once/3s flash, keep output

Protection@-5℃

once/1s flash, relay cut off

WarningRelease@5℃


ProtectionRelease@0℃



LCD Module Introduction
The LCD display battery and inverter working information in the cabinet

Function description


Item

Name

Description

1

INV power switch

Power saver auto: inverter work in saver mode

Inverter OFF: inverter power off

Inverter ON: inverter work in normal mode

2

Inverter indicator LED

CHG: inverter working in battery charge mode

INV: inverter working in battery discharge mode

Alarm: inverter warning or fault

3

LCD Screen

Show the system working information

4

Battery indicator LED

RUN: battery working normal

Alarm: battery warning or fault

Display ON/OFF

5

Button SYS

Press button, LCD will show ESS info directly

Button BATT

Press button, LCD will show BATT info directly

Button INV

Press button, LCD will show INV info directly

Button MPPT

Press button, LCD will show MPPT info directly



Note:
1. The connector of Inverter port is RJ45 type, connector of Battery is RJ11 type, never insert the wrong position or damage will happen and invalid warranty.
2. DISPLAY ON/OFF: touch any button will lighting the LCD, keep press the button, the current screen will hold for checking current module information.
Display introduction
ESS INFO display



Charging-Power

 MPPT charging power total

Energy-hour

 Solar generator energy in current hour

Energy-Day

Solar generator energy today

Energy-Total

Solar generator energy total

AC Load

Current AC loads power inverter take

BAT-Voltage

System battery voltage

Total Bat capacity

System rated battery capacity in total

Remain Bat capacity

System remain battery capacity in total

Discharge-Time

System estimated time to discharge battery empty in current condition

Charge- Time

System estimated time to charging battery full in current condition

MPPT-Status

All MPPT working status in system

00: normal  01: warning occur  02: fault occur

Inverter-Status

Inverter working status in system

00: normal  01: warning occur  02: fault occur

Battery-Status

All Battery working status in system

00: normal  01: warning occur  02: fault occur


BATTERY PACK display


first battery info window

Total-battery pack

Total battery packs in system

Battery V:

Current ID battery voltage

Rated Cap:

Battery rated capacity of current ID

Current I:

Positive means charge, Negative means discharge

Current Cap:

Remain capacity of current ID battery

CHG time:

Estimated time to charging battery full

Current SOC:

Remain SOC of current ID battery

DIS time:

Estimated time to discharge battery empty

Cycle times:

Battery cycle times of current ID

ID:

Current battery identity number

Alarm status:

Ref the battery pack alarm code table

OVP times

Number of battery voltage alarm times

OCP times

Number of battery current alarm times

OTP times

Number of battery temperature alarm times


Battery pack alarm code table

0000

normal

0100

Cell Over-voltage Warning

0200

Cell Over-voltage Protection

0400

Cell Low-voltage Warning

0800

Cell Low-voltage Protection

0010

Cell Over-temp Warning

0020

Cell Over-temp Protection

0040

Cell Low-temp Warning

0080

Cell Low-temp Protection

0001

Discharge Over-current Warning

0002

Discharge Over-current Protection

0004

Charge Over-current Warning

0008

Charge Over-current Protection




second battery info window

ID

Current battery identity number

C1——C16

Internal cells voltage

T1——T4

Internal temperature detecting value

Max V

Maximum cell voltage

Min V

Minimum cell voltage

Max T

Maximum internal temperature detecting value

Min T

Minimum internal temperature detecting value


INVERTER INFO display


Rated-Power

Inverter rated power

Input AC

Current utility or generator AC voltage

Output AC

Inverter output AC voltage

Batt DC

Current battery voltage

Output Freq

Inverter output AC frequency

Output Load

Current AC loads percentage inverter take

Work mode

Charging or Inverter

Mode Transfer times

Inverter working mode transfer times

Alarm

Ref inverter 3.3.9

Fault

Ref inverter 3.3.9




MPPT INFO display


ID

Current MPPT identity number

PV Input Voltage

Current MPPT PV input voltage

Charging Current

Current MPPT charging current

Charging Power

Current MPPT charging power

Charge Voltage

Current MPPT charging voltage

Unit HS Temperature

Current MPPT internal temperature

Warning code

Ref MPPT 3.1.3

Fault code

Ref MPPT 3.1.3

Fault times

Current MPPT occurs fault times


Storage & Transportation
* Based on the character of cell, proper environment for transportation of LiFePO4 battery pack need to be created to protect the battery.
* Battery should be stayed in the ware house -20℃~35℃ where it’s dry, clean, shade, and well-ventilated.
* The battery should be stored in 50% SOC during transportation.
* The battery need to be charged every 6 months if out of use.
* Keep the battery against dropping, turning over and serious stacking during loading.

Warning & Tips
Please read and follow the specification and caution remarks on battery surface before use the battery. Improper use may cause heat, fire, rupture, damage or capacity deterioration of the battery. Describes is not responsible for any accidents caused by the usage without following our specification.
Warning!
* The battery must be far away from heat source, high voltage, and avoid to be exposed in sunshine for long time.
* Never throw the battery into water.
* Never connect the positive and negative of battery with metal.
* Never sheep or store battery together with metal.
* Never reverse two electrodes when use the battery.
* Never disassemble the battery without manufacturer's permission and guidance.
* Never knock, throw or trample the battery.
Tips!
* Keep the battery against high temperature. Otherwise it will cause battery heat, get into fire or lose some function and reduce the life.
* When battery run out of power, please charge your battery timely (≤15day).
* Please use the matched or suggested charger for this battery.
* If battery emit peculiar smell, heating, distortion or appear any abnormity during working or storage, please stop using and take it out from device.
* If the battery leaks and get into the eyes or skin, do not wipe, instead, rinse it with clean water and see doctor immediately.
* Please far away from children or pets.
* Do not put disuse battery into a fire or water.
* It is strictly prohibited any series between the battery packs.

Welcome to our website. If you have any requests or suggestions,please feel free to email us at yiyen@yiyen.com or use the following enquiry form. Please allow us to provide you with the best service.