Battery | Description | |||
Normal specification | ||||
1 | Rated Voltage | 51.2V | ||
2 | Rated Capacity | 800Ah | ||
3 | Rated Energy | 40.96KWH | ||
4 | Battery Configuration | 10.24KWH(16S2P) *4PCS | ||
5 | Battery Cell | 3.2V100AH 128PCS | ||
Standard Charge | ||||
1 | Operation temperature range @charging | 0~45℃ | ||
2 | Rated charge voltage | 55.2±0.4V | ||
3 | Max charge voltage | 56.8±0.4V | ||
4 | Overcharge protection | 58.4±0.4V | ||
5 | Allowed MAX charge current(Total) | 440A withstand 30s (every pack 55A) | ||
6 | Peak charge current(Total) | 480A withstand 5s (every pack 60A) | ||
7 | Rated charge current(Total) | 400A (every pack 100A) | ||
8 | Recommend charge current(Total) | <300A | ||
Standard discharge | ||||
1 | Operation temperature range @discharging | -20~60℃ | ||
2 | Output Voltage Range | 40~56Vdc | ||
3 | Recommend Working Range | 46~54Vdc | ||
4 | Discharge Cut-off voltage | 40V | ||
5 | Allowed MAX discharge current(Total) | 880A withstand 30s (every pack 110A) | ||
6 | Peak discharge current(Total) | 960A withstand 5s (every pack 120A) | ||
7 | Rated discharge current(Total) | 800A (every pack 200A) | ||
8 | Recommend discharge current(Total) | <600A | ||
Communication | ||||
1 | RS485 | For LCD remote | ||
2 | CAN | PC control and monitor | ||
Inverter (built-in) | Description | |||
Normal specification | ||||
1 | Rated Power | 15KW | ||
2 | Output Waveform | Pure Sine Wave/Same as input (Bypass Mode) | ||
3 | Output Voltage | 240Vac(H-H)/120Vac(H-N) ±10% RMS | ||
4 | Output Frequency | 50 or 60± 0.3Hz (Inverter mode by sw4 setting) | ||
5 | Typical Transfer Time | 4-6ms typical,10ms(Max) | ||
6 | THD | < 3%(Rated voltage full R load) | ||
7 | AC Input Range | 184-253Vac (UPS mode) or 140-270Vac (GEN mode) | ||
8 | Customized AC Charger | Battery type selector position 9, special design for LFP, make the battery cycle life Maximization | ||
9 | MAX AC Charge Current | 100A | ||
10 | Battery priority Function | Setting by SW5 on position 1 (inverter mode valid), AC automatic come in when battery voltage low alarm at 48Vdc or 50Vdc | ||
11 | AC Bypass without charging | Battery type selector position 0 | ||
MPPT (built-in) | Description | |||
Normal specification | ||||
1 | PV POWER | 3.5KW*4 | ||
2 | PV Input Voltage | 60-145Vdc | ||
3 | MPPT Charging Voltage | 56.0Vdc (Fast charging)/54Vdc (Float charging) | ||
4 | MPPT Output Current | 60A*4 | ||
Model | Configuration | |||
ESS15048E800P4 | MPPT | INVERTER | BATTERY | Energy |
240A(50A*4) | 15KW | 800AH(200AH*4) | 40.96kwh | |
Mechanical Characteristics | ||||
ESS15048E800P4 | Dimension H*W*D | Shipping H*W*D | Weight(N.W.) | Weight(G.W.) |
1610*560*960mm | 1790*700*1050mm | 560KG | 610KG |
Items |
Content (for each cell) |
Criterion |
Alarm LED(red) |
Over charge |
Over-chargewarning |
3700mv |
once/3s flash, keep output |
Over-charge protection |
3750mv |
once/1s flash, relay cut off |
|
Over-chargewarningrelease |
3400mv |
|
|
Over-charge protectionrelease |
3350mv |
|
|
Over-chargerelease method |
Discharging(Automatic) |
|
|
Over discharge |
Over-dischargewarning |
2700mv |
once/3s flash, keep output |
Over-discharge protection |
2500mv |
once/1s flash, relay cut off |
|
Over-dischargewarningrelease |
2900mv |
|
|
Over-discharge protectionrelease |
2800mv |
|
|
Over-dischargerelease method |
Charging |
|
|
Over current (CHG&DISCHG) |
Overcurrent warning |
110% rated |
once/1s flash, 30s off |
Overcurrent protection(PEAK) |
120% rated |
Lightning, delay 10s off relay cut off |
|
Overcurrentrelease method(CHG) |
Restart |
|
|
Overcurrentrelease method(DISCHG) |
Cut off loads and Restart |
|
|
Over & Lower Temp (Discharging) |
Overtemperature |
Warning@55℃ |
once/3s flash, keep output |
Protection@60℃ |
once/1s flash, relay cut off |
||
WarningRelease@40℃ |
|
||
ProtectionRelease@55℃ |
|
||
Lower temperature |
Warning@-20℃ |
once/3s flash, keep output |
|
Protection@-25℃ |
once/1s flash, relay cut off |
||
WarningRelease@-15℃ |
|
||
ProtectionRelease@-20℃ |
|
||
Over & Lower Temp(Charging) |
Overtemperature |
Warning@45℃ |
once/3s flash, keep output |
Protection@50℃ |
once/1s flash, relay cut off |
||
WarningRelease@40℃ |
|
||
ProtectionRelease@45℃ |
|
||
Lower temperature |
Warning@0℃ |
once/3s flash, keep output |
|
Protection@-5℃ |
once/1s flash, relay cut off |
||
WarningRelease@5℃ |
|
||
ProtectionRelease@0℃ |
|
|
|
|
|
ESS15048E800P4-40.96KWH Single-phase off-grid energy storage system |
|||
DOWNLOAD PDF |
Item |
Name |
Description |
1 |
INV power switch |
Power saver auto: inverter work in saver mode |
Inverter OFF: inverter power off |
||
Inverter ON: inverter work in normal mode |
||
2 |
Inverter indicator LED |
CHG: inverter working in battery charge mode |
INV: inverter working in battery discharge mode |
||
Alarm: inverter warning or fault |
||
3 |
LCD Screen |
Show the system working information |
4 |
Battery indicator LED |
RUN: battery working normal |
Alarm: battery warning or fault |
||
Display ON/OFF |
||
5 |
Button SYS |
Press button, LCD will show ESS info directly |
Button BATT |
Press button, LCD will show BATT info directly |
|
Button INV |
Press button, LCD will show INV info directly |
|
Button MPPT |
Press button, LCD will show MPPT info directly |
Charging-Power |
MPPT charging power total |
Energy-hour |
Solar generator energy in current hour |
Energy-Day |
Solar generator energy today |
Energy-Total |
Solar generator energy total |
AC Load |
Current AC loads power inverter take |
BAT-Voltage |
System battery voltage |
Total Bat capacity |
System rated battery capacity in total |
Remain Bat capacity |
System remain battery capacity in total |
Discharge-Time |
System estimated time to discharge battery empty in current condition |
Charge- Time |
System estimated time to charging battery full in current condition |
MPPT-Status |
All MPPT working status in system 00: normal 01: warning occur 02: fault occur |
Inverter-Status |
Inverter working status in system 00: normal 01: warning occur 02: fault occur |
Battery-Status |
All Battery working status in system 00: normal 01: warning occur 02: fault occur |
Total-battery pack |
Total battery packs in system |
Battery V: |
Current ID battery voltage |
Rated Cap: |
Battery rated capacity of current ID |
Current I: |
Positive means charge, Negative means discharge |
Current Cap: |
Remain capacity of current ID battery |
CHG time: |
Estimated time to charging battery full |
Current SOC: |
Remain SOC of current ID battery |
DIS time: |
Estimated time to discharge battery empty |
Cycle times: |
Battery cycle times of current ID |
ID: |
Current battery identity number |
Alarm status: |
Ref the battery pack alarm code table |
OVP times |
Number of battery voltage alarm times |
OCP times |
Number of battery current alarm times |
OTP times |
Number of battery temperature alarm times |
0000 |
normal |
0100 |
Cell Over-voltage Warning |
0200 |
Cell Over-voltage Protection |
0400 |
Cell Low-voltage Warning |
0800 |
Cell Low-voltage Protection |
0010 |
Cell Over-temp Warning |
0020 |
Cell Over-temp Protection |
0040 |
Cell Low-temp Warning |
0080 |
Cell Low-temp Protection |
0001 |
Discharge Over-current Warning |
0002 |
Discharge Over-current Protection |
0004 |
Charge Over-current Warning |
0008 |
Charge Over-current Protection |
ID |
Current battery identity number |
C1——C16 |
Internal cells voltage |
T1——T4 |
Internal temperature detecting value |
Max V |
Maximum cell voltage |
Min V |
Minimum cell voltage |
Max T |
Maximum internal temperature detecting value |
Min T |
Minimum internal temperature detecting value |
Rated-Power |
Inverter rated power |
Input AC |
Current utility or generator AC voltage |
Output AC |
Inverter output AC voltage |
Batt DC |
Current battery voltage |
Output Freq |
Inverter output AC frequency |
Output Load |
Current AC loads percentage inverter take |
Work mode |
Charging or Inverter |
Mode Transfer times |
Inverter working mode transfer times |
Alarm |
Ref inverter 3.3.9 |
Fault |
Ref inverter 3.3.9 |
ID |
Current MPPT identity number |
PV Input Voltage |
Current MPPT PV input voltage |
Charging Current |
Current MPPT charging current |
Charging Power |
Current MPPT charging power |
Charge Voltage |
Current MPPT charging voltage |
Unit HS Temperature |
Current MPPT internal temperature |
Warning code |
Ref MPPT 3.1.3 |
Fault code |
Ref MPPT 3.1.3 |
Fault times |
Current MPPT occurs fault times |
Battery | Description | |||
Normal specification | ||||
1 | Rated Voltage | 51.2V | ||
2 | Rated Capacity | 800Ah | ||
3 | Rated Energy | 40.96KWH | ||
4 | Battery Configuration | 10.24KWH(16S2P) *4PCS | ||
5 | Battery Cell | 3.2V100AH 128PCS | ||
Standard Charge | ||||
1 | Operation temperature range @charging | 0~45℃ | ||
2 | Rated charge voltage | 55.2±0.4V | ||
3 | Max charge voltage | 56.8±0.4V | ||
4 | Overcharge protection | 58.4±0.4V | ||
5 | Allowed MAX charge current(Total) | 440A withstand 30s (every pack 55A) | ||
6 | Peak charge current(Total) | 480A withstand 5s (every pack 60A) | ||
7 | Rated charge current(Total) | 400A (every pack 100A) | ||
8 | Recommend charge current(Total) | <300A | ||
Standard discharge | ||||
1 | Operation temperature range @discharging | -20~60℃ | ||
2 | Output Voltage Range | 40~56Vdc | ||
3 | Recommend Working Range | 46~54Vdc | ||
4 | Discharge Cut-off voltage | 40V | ||
5 | Allowed MAX discharge current(Total) | 880A withstand 30s (every pack 110A) | ||
6 | Peak discharge current(Total) | 960A withstand 5s (every pack 120A) | ||
7 | Rated discharge current(Total) | 800A (every pack 200A) | ||
8 | Recommend discharge current(Total) | <600A | ||
Communication | ||||
1 | RS485 | For LCD remote | ||
2 | CAN | PC control and monitor | ||
Inverter (built-in) | Description | |||
Normal specification | ||||
1 | Rated Power | 15KW | ||
2 | Output Waveform | Pure Sine Wave/Same as input (Bypass Mode) | ||
3 | Output Voltage | 240Vac(H-H)/120Vac(H-N) ±10% RMS | ||
4 | Output Frequency | 50 or 60± 0.3Hz (Inverter mode by sw4 setting) | ||
5 | Typical Transfer Time | 4-6ms typical,10ms(Max) | ||
6 | THD | < 3%(Rated voltage full R load) | ||
7 | AC Input Range | 184-253Vac (UPS mode) or 140-270Vac (GEN mode) | ||
8 | Customized AC Charger | Battery type selector position 9, special design for LFP, make the battery cycle life Maximization | ||
9 | MAX AC Charge Current | 100A | ||
10 | Battery priority Function | Setting by SW5 on position 1 (inverter mode valid), AC automatic come in when battery voltage low alarm at 48Vdc or 50Vdc | ||
11 | AC Bypass without charging | Battery type selector position 0 | ||
MPPT (built-in) | Description | |||
Normal specification | ||||
1 | PV POWER | 3.5KW*4 | ||
2 | PV Input Voltage | 60-145Vdc | ||
3 | MPPT Charging Voltage | 56.0Vdc (Fast charging)/54Vdc (Float charging) | ||
4 | MPPT Output Current | 60A*4 | ||
Model | Configuration | |||
ESS15048E800P4 | MPPT | INVERTER | BATTERY | Energy |
240A(50A*4) | 15KW | 800AH(200AH*4) | 40.96kwh | |
Mechanical Characteristics | ||||
ESS15048E800P4 | Dimension H*W*D | Shipping H*W*D | Weight(N.W.) | Weight(G.W.) |
1610*560*960mm | 1790*700*1050mm | 560KG | 610KG |
Items |
Content (for each cell) |
Criterion |
Alarm LED(red) |
Over charge |
Over-chargewarning |
3700mv |
once/3s flash, keep output |
Over-charge protection |
3750mv |
once/1s flash, relay cut off |
|
Over-chargewarningrelease |
3400mv |
|
|
Over-charge protectionrelease |
3350mv |
|
|
Over-chargerelease method |
Discharging(Automatic) |
|
|
Over discharge |
Over-dischargewarning |
2700mv |
once/3s flash, keep output |
Over-discharge protection |
2500mv |
once/1s flash, relay cut off |
|
Over-dischargewarningrelease |
2900mv |
|
|
Over-discharge protectionrelease |
2800mv |
|
|
Over-dischargerelease method |
Charging |
|
|
Over current (CHG&DISCHG) |
Overcurrent warning |
110% rated |
once/1s flash, 30s off |
Overcurrent protection(PEAK) |
120% rated |
Lightning, delay 10s off relay cut off |
|
Overcurrentrelease method(CHG) |
Restart |
|
|
Overcurrentrelease method(DISCHG) |
Cut off loads and Restart |
|
|
Over & Lower Temp (Discharging) |
Overtemperature |
Warning@55℃ |
once/3s flash, keep output |
Protection@60℃ |
once/1s flash, relay cut off |
||
WarningRelease@40℃ |
|
||
ProtectionRelease@55℃ |
|
||
Lower temperature |
Warning@-20℃ |
once/3s flash, keep output |
|
Protection@-25℃ |
once/1s flash, relay cut off |
||
WarningRelease@-15℃ |
|
||
ProtectionRelease@-20℃ |
|
||
Over & Lower Temp(Charging) |
Overtemperature |
Warning@45℃ |
once/3s flash, keep output |
Protection@50℃ |
once/1s flash, relay cut off |
||
WarningRelease@40℃ |
|
||
ProtectionRelease@45℃ |
|
||
Lower temperature |
Warning@0℃ |
once/3s flash, keep output |
|
Protection@-5℃ |
once/1s flash, relay cut off |
||
WarningRelease@5℃ |
|
||
ProtectionRelease@0℃ |
|
Item |
Name |
Description |
1 |
INV power switch |
Power saver auto: inverter work in saver mode |
Inverter OFF: inverter power off |
||
Inverter ON: inverter work in normal mode |
||
2 |
Inverter indicator LED |
CHG: inverter working in battery charge mode |
INV: inverter working in battery discharge mode |
||
Alarm: inverter warning or fault |
||
3 |
LCD Screen |
Show the system working information |
4 |
Battery indicator LED |
RUN: battery working normal |
Alarm: battery warning or fault |
||
Display ON/OFF |
||
5 |
Button SYS |
Press button, LCD will show ESS info directly |
Button BATT |
Press button, LCD will show BATT info directly |
|
Button INV |
Press button, LCD will show INV info directly |
|
Button MPPT |
Press button, LCD will show MPPT info directly |
Charging-Power |
MPPT charging power total |
Energy-hour |
Solar generator energy in current hour |
Energy-Day |
Solar generator energy today |
Energy-Total |
Solar generator energy total |
AC Load |
Current AC loads power inverter take |
BAT-Voltage |
System battery voltage |
Total Bat capacity |
System rated battery capacity in total |
Remain Bat capacity |
System remain battery capacity in total |
Discharge-Time |
System estimated time to discharge battery empty in current condition |
Charge- Time |
System estimated time to charging battery full in current condition |
MPPT-Status |
All MPPT working status in system 00: normal 01: warning occur 02: fault occur |
Inverter-Status |
Inverter working status in system 00: normal 01: warning occur 02: fault occur |
Battery-Status |
All Battery working status in system 00: normal 01: warning occur 02: fault occur |
Total-battery pack |
Total battery packs in system |
Battery V: |
Current ID battery voltage |
Rated Cap: |
Battery rated capacity of current ID |
Current I: |
Positive means charge, Negative means discharge |
Current Cap: |
Remain capacity of current ID battery |
CHG time: |
Estimated time to charging battery full |
Current SOC: |
Remain SOC of current ID battery |
DIS time: |
Estimated time to discharge battery empty |
Cycle times: |
Battery cycle times of current ID |
ID: |
Current battery identity number |
Alarm status: |
Ref the battery pack alarm code table |
OVP times |
Number of battery voltage alarm times |
OCP times |
Number of battery current alarm times |
OTP times |
Number of battery temperature alarm times |
0000 |
normal |
0100 |
Cell Over-voltage Warning |
0200 |
Cell Over-voltage Protection |
0400 |
Cell Low-voltage Warning |
0800 |
Cell Low-voltage Protection |
0010 |
Cell Over-temp Warning |
0020 |
Cell Over-temp Protection |
0040 |
Cell Low-temp Warning |
0080 |
Cell Low-temp Protection |
0001 |
Discharge Over-current Warning |
0002 |
Discharge Over-current Protection |
0004 |
Charge Over-current Warning |
0008 |
Charge Over-current Protection |
ID |
Current battery identity number |
C1——C16 |
Internal cells voltage |
T1——T4 |
Internal temperature detecting value |
Max V |
Maximum cell voltage |
Min V |
Minimum cell voltage |
Max T |
Maximum internal temperature detecting value |
Min T |
Minimum internal temperature detecting value |
Rated-Power |
Inverter rated power |
Input AC |
Current utility or generator AC voltage |
Output AC |
Inverter output AC voltage |
Batt DC |
Current battery voltage |
Output Freq |
Inverter output AC frequency |
Output Load |
Current AC loads percentage inverter take |
Work mode |
Charging or Inverter |
Mode Transfer times |
Inverter working mode transfer times |
Alarm |
Ref inverter 3.3.9 |
Fault |
Ref inverter 3.3.9 |
ID |
Current MPPT identity number |
PV Input Voltage |
Current MPPT PV input voltage |
Charging Current |
Current MPPT charging current |
Charging Power |
Current MPPT charging power |
Charge Voltage |
Current MPPT charging voltage |
Unit HS Temperature |
Current MPPT internal temperature |
Warning code |
Ref MPPT 3.1.3 |
Fault code |
Ref MPPT 3.1.3 |
Fault times |
Current MPPT occurs fault times |